Study finds CS 3600 scanner gives most accurate results

Article

When scanning a single crown, the Carestream intraoral scanner was found to have the best trueness and precision.

The CS 3600 intraoral scanner was found to give the most accurate results during a new study titled “Trueness and Precision of Five Intraoral Scanners in the Impressions of Single and Multiple Implants: A Comparative In-Vitro Study.”1

With few peer-reviewed studies evaluating the clinical efficacy of intraoral scanners in implantology, these latest findings from Drs. Francesco Guido Mangano, Uli Hauschild, Giovanni Veronesi, Mario Imburgia, Carlo Mangano and Oleg Admakin compared the trueness and precision of five intraoral scanners and determined which have both accurate and consistent results.

According to the study, the CS 3600 had the best accuracy while having the fewest triangles making up the meshes in all applications.

Related reading: Carestream Dental creates software partner program

“The number of triangles is often misinterpreted to be a measure of acquisition resolution or mesh quality,” says Victor Wong, Ph.D., director, research and innovation, Carestream Dental. “In fact, by having the best trueness with the smallest number of triangles, the CS 3600 demonstrates the most efficient/optimal mesh generation by placing more triangles in areas with more details, and vice versa, with minimized mesh file size while maintaining accuracy.”

To put the scanners to the test, 10 scans were performed by a single digital dentistry expert per indication per intraoral scanner with a zig-zag technique in the same environmental conditions. Two maxilla plaster models were used as a reference: one partially edentulous and one totally edentulous.

In this study, trueness was defined by the difference between the scanned model and the reference model; precision was quantified by the difference between repeatedly scanned models. In both cases, smaller values indicated greater trueness and/or precision. A scanner needs both trueness and precision to be considered accurate.

Trending article: Seeing the same dimensions as we operate

According to the results of the study, when scanning a single crown, the CS 3600 was found to have the best trueness (15.2 ±0.8 μm) and the best precision (11.3 ±1.1 μm). The CS 3600 also had the best trueness (23 ±1.1 μm) and the best precision (21 ±1.9 μm) when scanning a partial prosthesis. While scanning a full arch, the CS 3600 had the best trueness (44.9 ±8.9 μm) and had the second-best precision (35.7 ± 4.3), which very closely follows the best precision result (35.6 ± 3.4).

This reportedly isn't the first time that studies have confirmed the CS 3600’s high performance. In a 2018 study,2 the CS 3600 outperformed other scanners, along with traditional impressions, in finish line accuracy. Its trueness was confirmed by a 2017 study that tested the accuracy of four intraoral scanners in oral implantology.3

To learn more about the CS 3600, visit carestreamdental.com.

References

1. Mangano F, Logozzo S, Hauschild U, Veronesi G, Imburgia M, Mangano C, Admakin O. June 6, 2019. Trueness and precision of 5 intraoral scanners in the impressions of single and multiple implants: a comparative in vitro study. BMC Oral Health. 19(101): DOI 10.1186/s12903-019-0792-7.

2. Nedelcu R, Nystrom I, Olsson P, Thor A. Feb. 26, 2018. Finish Line Distinctness and Accuracy in 7 Intraoral Scanners versus Conventional Impression: An In-vitro Descriptive Comparison. BMC Oral Health.18(27): DOI 10.1186/s12903-018-0489-3.

3. Imburgia M, Logozzo S, Hauschild U, Veronesi G, Mangano G, Mangano FG. June 2, 2017. Accuracy of Four Intraoral Scanners in Oral Implantology: A Comparative In-Vitro Study. BMC Oral Health. 17(92): DOI 10.1186/s12903-017-0383-4.

Related Videos
CDS 2024: What's New at TAG University? with Andrew De la Rosa, DMD
CDS 2024: Breaking Down Barriers to Care with Eric Kukucka, DD
GNYDM23 Product Focus: CandidPro with Kristin Lange, VP of Sales at Candid
The Connected Future of Dental CAD/CAM with Max Milz
Greater New York Dental Meeting 2023 – Interview with Daniel Weinstein from Lura Health
2023 Chicago Dental Society Midwinter Meeting, Interview with Brant Herman, CEO and Founder at MouthWatch and Dentistry.One
Greater New York Dental Meeting 2021 - Interview with Marty Jablow, DMD
 Greater New York Dental Meeting 2021 - Interview with PlanetDDS Vice President of Sales Mike Huffaker
Dentsply Sirona World 2021 - Press Conference
Related Content
© 2024 MJH Life Sciences

All rights reserved.